MARS Materials Database Miller Advanced Research Solutions Center
Dana Whitaker, Research Engineer
View as Research engineer Data administrator Student intern
Overview / Ovens and furnaces

Ovens and furnaces

Grieve Oven post-cure and anneal cycles and Small GCF pyrolysis cycles. Each cycle is matched to its part through ION, then checked for data coverage and soak deviation. Source table mars.gold.thermal_cycle.
Export CSV
CycleMachinePurposePartStarted (desc) Peak setpoint (C)Soak (min)Max soak dev. (C) Coverage %Result
GCF-S-0405-1Small GCFPIP pyrolysisMARS-26-0405 09/03/2026 09:131,200.02003.90 100.0Within tolerance
GCF-S-0404-4Small GCFPIP pyrolysisMARS-26-0404 09/03/2026 08:221,000.01605.20 100.0Within tolerance
GO-RUN-18887Grieve OvenPost-cure 177CMARS-26-0405 09/01/2026 20:05177.03251.50 99.8Within tolerance
GCF-S-0404-3Small GCFPIP pyrolysisMARS-26-0404 09/01/2026 06:411,000.03104.50 100.0Within tolerance
GCF-S-0404-2Small GCFPIP pyrolysisMARS-26-0404 08/30/2026 05:341,000.04305.60 100.0Within tolerance
GCF-S-0404-1Small GCFPIP pyrolysisMARS-26-0404 08/28/2026 13:101,200.03353.60 100.0Within tolerance
GO-RUN-18855Grieve OvenPost-cure 177CMARS-26-0404 08/25/2026 20:10177.03311.60 99.8Within tolerance
Showing 201 to 207 of 207 cycles Page 9 of 9 Previous page

Data as of pipeline run R-20261105-0200, finished 11/05/2026 02:00 Mountain. Tables: mars.gold and mars.ops.