Overview
46 parts tracked: 10 in process, 36 inspected. 5 open alerts.
Parts in process
| Part | Program | Current step | PIP cycles | Last activity |
|---|---|---|---|---|
| MARS-26-0435 | Nozzle throat insert, subscale | Surface grind a-bars | 6 | 11/04/2026 21:32 |
| MARS-26-0449 | Hot structure panel | Polymer Infiltration and Pyrolysis Cycle | 1 | 11/04/2026 17:02 |
| MARS-26-0433 | Leading edge coupons, C/SiC | Surface grind a-bars | 6 | 11/04/2026 16:32 |
| MARS-26-0440 | Leading edge coupons, C/SiC | Polymer Infiltration and Pyrolysis Cycle | 6 | 11/04/2026 16:01 |
| MARS-26-0438 | Leading edge coupons, C/SiC | Surface grind a-bars | 5 | 11/04/2026 15:22 |
| MARS-26-0445 | Leading edge coupons, C/SiC | Polymer Infiltration and Pyrolysis Cycle | 3 | 11/04/2026 07:27 |
| MARS-26-0447 | Leading edge coupons, C/SiC | Polymer Infiltration and Pyrolysis Cycle | 2 | 11/03/2026 21:37 |
| MARS-26-0444 | Nozzle throat insert, subscale | Polymer Infiltration and Pyrolysis Cycle | 3 | 11/03/2026 00:24 |
| MARS-26-0448 | Leading edge coupons, C/SiC | Grieve Oven Operation | 0 | 11/02/2026 14:26 |
| MARS-26-0432 | Leading edge coupons, C/SiC | Surface grind a-bars | 4 | 10/29/2026 07:25 |
Recent pipeline runs
| Run | Started | Status | Files | Quarantined rows | Open alerts |
|---|---|---|---|---|---|
| R-20261105-0200 | 11/05/2026 02:00 | Succeeded | 23 | 0 | 5 |
| R-20261104-0200 | 11/04/2026 02:00 | Succeeded | 22 | 0 | 5 |
| R-20261103-0200 | 11/03/2026 02:00 | Succeeded | 16 | 0 | 5 |
| R-20261102-0200 | 11/02/2026 02:00 | Succeeded | 22 | 0 | 5 |
| R-20261101-0200 | 11/01/2026 02:00 | Succeeded | 7 | 0 | 5 |
| R-20261031-0200 | 10/31/2026 02:00 | Succeeded | 18 | 0 | 5 |
Open alerts
Low GO-RUN-19244
Grieve Oven cycle GO-RUN-19244 for MARS-26-0421 deviated 5.8 C from setpoint during the soak (tolerance 5.0 C). Review before releasing the part.
A-1041, opened 10/27/2026 02:00
Low GO-RUN-19542
Grieve Oven cycle GO-RUN-19542 for MARS-26-0436 deviated 5.3 C from setpoint during the soak (tolerance 5.0 C). Review before releasing the part.
A-1042, opened 10/27/2026 02:00
Low GO-RUN-19557
Grieve Oven cycle GO-RUN-19557 for MARS-26-0438 deviated 6.4 C from setpoint during the soak (tolerance 5.0 C). Review before releasing the part.
A-1043, opened 10/27/2026 02:00
Low IMG_46961.json
Sample ID "MARS-26-040" entered on the Digital Optical Microscope does not match a part in ION. The image is loaded but not linked to a part.
A-1044, opened 10/27/2026 02:00
Low IMG_28431.json
Sample ID "MARS-26-041" entered on the Digital Optical Microscope does not match a part in ION. The image is loaded but not linked to a part.
A-1045, opened 10/27/2026 02:00
Source freshness
| Machine | Last file | Files |
|---|---|---|
| CF3D Robot | 11/01/2026 04:04 | 38 |
| Juggerbot 3D Printer | 10/20/2026 03:15 | 8 |
| Digital Optical Microscope | 11/05/2026 01:22 | 142 |
| SEM | 11/04/2026 22:27 | 90 |
| Optical Profilometer | 11/05/2026 01:02 | 76 |
| Coordinate Measuring Machine (CMM) | 11/05/2026 00:30 | 38 |
| ION Procedures | 11/04/2026 23:30 | 71 |
| Grieve Oven | 11/03/2026 23:59 | 43 |
| Small GCF | 11/05/2026 00:28 | 162 |
Data as of pipeline run R-20261105-0200, finished 11/05/2026 02:00 Mountain. Tables: mars.gold and mars.ops.